Leading Post Tension Company in the UAE, Serving All Seven Emirates
Premium Post Tension Concrete Works is a post tension company in UAE that designs, installs, stresses and grouts post-tensioned slabs for the contractors, consultants and developers building across the Emirates. Licensed, PTI certified, and on site with you from the first shop drawing to the final cube test.
What we do
Which Services Does Our Post Tension Company in UAE Provide?
Post-tensioning is not a single trade. It runs from the structural design that decides where each tendon sits, through the materials, the on-site installation, the stressing operation, the grouting, and the testing that lets the consultant sign the slab off. We handle all seven stages in-house, which means one team is accountable for the slab from the drawing board to the day it carries load.
Seven services. One accountable specialist contractor.
Post-Tension Design
PT slab and beam design, transfer girder design, structural optimisation, shop drawings and calculations.
Explore service →Supply of Materials
PT strands, anchors and wedges, ducts, grouting accessories, chairs and couplers, delivered to programme.
Explore service →Installation
Tendon layout and fixing, anchor installation, strand threading, and full coordination with the reinforcement works.
Explore service →Stressing Operations
Hydraulic jack stressing, elongation monitoring, stressing reports, and the quality checks that back them up.
Explore service →Grouting Works
Cement grout preparation, duct grouting, grout testing and quality assurance for long-term tendon protection.
Explore service →Inspection and Testing
Material testing, anchor inspection, load testing, and third-party verification support.
Explore service →Repair and Rehabilitation
Tendon investigation, PT tendon repair and replacement, and structural strengthening for existing slabs.
Explore service →Why a specialist
What Makes Premium Post Tension Different From a General Contractor?
Plenty of firms offer post-tensioning in the UAE, but very few are genuine post-tensioning specialists. That shortage is not an abstract problem. It shows up as a slab that waits for a stressing crew, a consultant who cannot get the documentation needed to release the next pour, and a main contractor absorbing the programme delay that follows.
We built this company to close that gap. Because the design, the materials, the installation, the stressing, the grouting and the testing all sit with one team, there is no handover point where responsibility gets blurred and nobody owns the delay. If the elongation figures come back outside tolerance, the people who designed the tendon profile are the same people standing at the jack.
Since starting operations in 2024 we have completed more than 40 projects with a team of over 50, working closely with the consultants and contractors who build across the UAE. As licensed post tension slab contractors in UAE, we work to Post-Tensioning Institute practice, and our stressing and cube-testing records are prepared to be handed straight to the consultant rather than reconstructed after the fact.
The result is a team UAE builders can schedule around with confidence. When you compare post tensioning contractors, ours will not always be the cheapest quotation on the table, but it is affordable post tensioning in the sense that matters on a live site: fewer surprises, fewer re-inspections, and a slab that clears sign-off the first time.
01
02
Site-ready records
03
Technical continuity
04
Programme confidence
UAE
Service areas
Which Emirates Does Premium Post Tension Work In?
Post-tensioning is now part of how the UAE builds, but it is used differently from one emirate to the next. In Dubai and Abu Dhabi it carries high-rise towers and podium structures, where transfer levels and long spans decide the frame. In Sharjah and the northern emirates it is the mid-rise residential block on a fixed plot, where a thinner slab and fewer columns turn directly into more usable floor area. Along the coast, durability and complete grouting matter as much as the design itself.
We take projects in all seven emirates. Each one builds differently, so rather than repeat the same claim seven times, we have written a page for each emirate covering how post-tensioning is actually being used there:
Start with your emirate's page, or simply call and we will tell you how we would approach your project.
Project evidence
Which Post-Tensioning Projects Have We Recently Completed?
Two of our recent project clusters give a fair picture of the range we cover.
Across all of this work our post-tensioned slabs have run between 220mm and 280mm thick, with steel ratios between 55 and 80 kg per cubic metre. Those are not marketing numbers. They are what the drawings actually called for once each building's spans, loads and geometry were worked through.
The process
How Does a Post-Tensioned Slab Come Together, From Design to Sign-Off?
Every project we take on runs through the same six stages, in the same order.
Design and shop drawings.
The tendon profile, the anchor positions and the slab thickness are worked out against the building's real spans and loads, then issued as drawings the site can build from.
Material supply.
Strands, anchors, wedges, ducts and accessories arrive scheduled against the pour, not ordered once the reinforcement is already tied.
Installation.
Tendons are laid to profile and fixed, anchors set, strands threaded, all coordinated with the rebar fixers rather than fought against them.
Stressing.
Once the concrete reaches the specified strength, tendons are stressed with hydraulic jacks and every elongation reading is recorded against the calculated figure.
Grouting.
Ducts are grouted to protect the tendons for the life of the structure, with the grout itself tested rather than assumed.
Cube testing and quality control.
The test results and stressing records are compiled into the documentation the consultant needs in order to sign off.
Read more about what happens on site during Installation and during Stressing Operations.
Every reading recorded. Every stage ready to audit.
6 controlled stages1 accountable teamQA records preparedField insights
What Have We Learned Building Post-Tensioned Structures in the UAE?
Client feedback
What Do Clients Say About Working With Premium Post Tension?
Common questions
FAQs for Contractors and Consultants Considering Post-Tensioning
What are post tension services?
Post-tensioning services cover everything needed to build a post-tensioned concrete slab: the structural design that positions the tendons, the supply of strands and anchors, the on-site installation of the tendons, the stressing operation that puts the steel under load, the grouting that protects the tendons afterwards, and the testing and documentation that let the consultant approve the work. Some companies provide only one or two of these stages. We provide all of them.
What are the disadvantages of post-tensioning?
The honest answer is that post-tensioning demands more coordination than conventional reinforced concrete. The tendon layout has to be right before the pour rather than corrected afterwards, later drilling or coring into the slab has to respect where the tendons run, and the work needs a crew that genuinely knows the system. Against that, you get longer spans, thinner slabs, fewer columns and better crack control. On most mid-rise and above projects in the UAE, that trade is worth making, but it is a trade, not a free upgrade.
Which emirates do you work in?
All seven. We take projects in Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah, Fujairah and Umm Al Quwain, and each emirate has its own page explaining how post-tensioning is used there. Our head office is where our crews and design team are based, so mobilising to any emirate is planned against your pour dates.
How thick does a post-tensioned slab need to be?
It depends on the spans, the loading and the building's geometry, so no single number is honest. As a real reference point, the post-tensioned slabs across our recent projects have fallen between 220mm and 280mm. The correct figure for your building comes out of the design, not out of a rule of thumb.
Are you licensed and certified?
Yes. We are a licensed post-tensioning contractor, registered for concrete works and pre-tension construction units building and execution works, and we are certified with the Post-Tensioning Institute. Both are verifiable, and we are happy to provide documentation with a quotation.
Start a project
Ready to Start Your Post-Tensioning Project in the UAE?
Send us the drawings, or just tell us the building type and the spans. We will tell you honestly whether post-tensioning is the right call for the structure, and what it would take to deliver it.
Friday: Closed
Request a quotation
Tell us about your project
Ajman headquarters